Power Supply Testing Process

Power Supply output is tested with an oscilloscope to ensure that it can maintain the proper output voltage under no traffic load and full traffic load conditions.

As an example, here are oscilloscope output images from a Cisco 3750 48 Port PoE Switch power supply that shows the DC No Load and DC Full Load voltage and the output waveform of the corresponding AC (ripple) voltages.

Power Supply Testing - Figure 1: Cisco 3750 DC oscilloscope output

Figure 1: Cisco 3750 DC oscilloscope output

Power Supply Testing - Figure 2: Cisco 3750 DC oscilloscope output

Figure 2: Cisco 3750 DC oscilloscope output

Zeriva technicians test each looking for deviations from these voltages and waveforms since deviations indicate internal power problems that may result in future failures.

As an example, here is an image from a failed 3750 48 PoE Switch Power Supply:

Power Supply Testing - Figure 3: Cisco 3750 failed PS DC output

Figure 3: Cisco 3750 failed power supply DC output